Back to catalog
  • Solar PV
  • SCADA
  • DAS
  • Modbus
  • SunSpec

Real Fault or Bad Data?

When monitoring data looks wrong, learn how to tell whether the equipment has a problem, or the data does.

Length
About 4 to 6 hours (estimated)
CE credits
NABCEP CEUs Pending Approval
Format
Self-paced

What you will be able to do

Planned for this course. The final list is confirmed by our subject matter experts before the course opens.

  • Follow a Reading from Sensor to Screen Trace how a measurement travels through meters, devices, loggers, and monitoring software to see where an error might enter.
  • Recognize Data You Cannot Trust Spot stale values, missing records, mismatched timestamps, and other data issues before using a reading to diagnose equipment.
  • Find Common Meter and Sensor Mistakes Investigate incorrect scaling, polarity, sensor setup, and reference measurements without assuming the equipment itself has failed.
  • Make Sense of Modbus and SunSpec Values Use documented point maps, data types, and scale factors to check whether raw device data is being interpreted correctly.
  • Separate a Real Fault from a Reporting Error Compare source readings and displayed values, narrow down the discrepancy, and identify what needs verification, correction, or escalation.

Course team

Lee Vernon Subject matter expert Solar commissioning · Co-Owner of RE:BOOT

With 33+ years in the electrical field and 20 years in solar, Lee has extensive experience in utility-scale PV commissioning, maintenance, and troubleshooting. His work spans field leadership, inverter technical support, and root-cause analysis, helping teams diagnose problems and improve solar asset reliability.

Darin Hadinger Course collaborator Solar commissioning · Founder of RE:BOOT

With 13+ years in renewable energy, Darin Hadinger has taught solar, wind, and microgrid courses and led workforce training for veterans and people returning from incarceration. His experience also spans commercial solar development, financing, and building RE: and its field services arm, RE Operations.

Devyn Pizzo Course developer Founder & CEO · ASCEND Education Group

Course outline

  1. 1. Understanding Where the Data Comes From

    When a monitoring system shows something unusual, the first question is whether the equipment is actually behaving that way. This section follows measurements from physical sensors and devices through data loggers, communication networks, and monitoring platforms. You'll learn how information moves through these systems and where errors or missing data can change what operators see.

  2. 2. Knowing When to Trust the Data

    Just because a value appears on a dashboard doesn't mean it's accurate or current. Explore how missing measurements, frozen readings, communication interruptions, timestamps, and data-processing differences can create misleading information. You'll practice recognizing when the available data is reliable enough to support a troubleshooting decision.

  3. 3. Understanding Metering and Sensor Problems

    Sometimes the equipment is working correctly, but the measurement system tells a different story. Learn how current transformers, voltage measurements, irradiance sensors, and environmental instruments contribute to plant monitoring. You'll examine how incorrect scaling, reversed measurements, sensor problems, and other errors can affect reported performance.

  4. 4. Making Sense of Modbus and SunSpec Data

    Monitoring systems rely on communication protocols and data formats to exchange equipment information. This section introduces how Modbus registers, SunSpec models, scaling factors, and device mappings affect the values displayed to operators. You'll work through examples of how a correct equipment reading can become misleading when the data is interpreted incorrectly.

  5. 5. Finding Where the Problem Starts

    When an equipment display and a monitoring platform disagree, how do you determine which one is right? Explore how to compare readings at different points in the data path to narrow down where a discrepancy begins. You'll investigate examples involving incorrect configurations, double-scaled measurements, swapped equipment labels, and communication issues.

  6. 6. Confirming the Correction

    Correcting a displayed value isn't enough unless you know the underlying problem has been resolved. Learn how to check corrected readings against suitable references, document configuration changes, and confirm that information is being reported consistently. The course concludes with a troubleshooting scenario where you'll distinguish possible equipment faults from measurement and data problems.